Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
-12.4…250 mbar
-5…100.4 inH2O
-1.24…25 kPa
-126…2550 mmWS
Process connection
threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Application
Special feature
Gold-plated contacts
Application
flush mountable for the food and beverage industry
Media
viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]
-25…150
Min. bursting pressure
30000 mbar
12044 inH2O
3000 kPa
Pressure rating
6000 mbar
2400 inH2O
600 kPa
Vacuum resistance [mbar]
-1000
Type of pressure
relative pressure; vacuum
No dead space
yes
Electrical data
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Integrated watchdog
yes
2-wire
Operating voltage [V]
20…30 DC
Current consumption [mA]
3.5…21.5
Power-on delay time [s]
< 1
3-wire
Operating voltage [V]
18…30 DC
Current consumption [mA]
5…45; (430 bei max. Laststrom)
Power-on delay time [s]
< 0.5
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs
2
Output signal
switching signal; analogue signal; IO-Link
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Number of analogue outputs
1
Analogue current output [mA]
4…20, invertible; (scalable)
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
2-wire
Max. load [Ω]
300
3-wire
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
100
Switching frequency DC [Hz]
125
Max. load [Ω]
(Ub – 10 V) / 21,5 mA; 650 Ω (Ub = 24 V)
Measuring/setting range
Measuring range
-12.4…250 mbar
-5…100.4 inH2O
-1.24…25 kPa
-126…2550 mmWS
Set point SP
-12…250 mbar
-4.8…100.4 inH2O
-1.2…25 kPa
-122…2549 mmWS
Reset point rP
-12.4…249.6 mbar
-5…100.2 inH2O
-1.24…24.96 kPa
-126…2545 mmWS
Analogue start point
-12.4…199.4 mbar
-5…80.1 inH2O
-1.24…19.94 kPa
-126…2033 mmWS
Analogue end point
38.2…250 mbar
15.3…100.4 inH2O
3.82…25 kPa
390…2549 mmWS
Min. difference between SP and rP
0.5 mbar
0.2 inH2O
0.05 kPa
5 mmWS
In steps of
0.1 mbar
0.1 inH2O
0.01 kPa
1 mmWS
Factory setting
SP1 =62.5 mbar
rP1 = 57.5 mbar
SP2 = 187.5 mbar
rP2 = 182.5 mbar
ASP = 0.00 mbar
AEP = 250 mbar
dAP = 2.00 s
dAA =2.00 s
Temperature monitoring
Measuring range
-25…150 °C
-13…302 °F
Accuracy / deviations
Switch point accuracy [% of the span]
< ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1)
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]
< ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Linearity deviation [% of the span]
< ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span]
< ± 0,15; (Turn down 1:1)
Long-term stability [% of the span]
< ± 0,1; (Turn down 1:1; per year)
Total deviation over temperature range
Temperature range
total deviation
-25…15 °C
Characteristics deviation ± 0,1 % der Spanne / 10 K
15…80 °C
Characteristics deviation
80…150 °C
Characteristics deviation ± 0,15 % der Spanne / 10 K
Notes on the accuracy / deviation
for further details see section Diagrams and graphs
Temperature monitoring
Accuracy [K]
± 2,5+ (0,08 x ( Umgebungstemperatur – Mediumtemperatur ))
Repeatability [K]
± 0,2
Resolution [K]
0.2
Response times
Damping process value dAP [s]
0…99.99
Damping for the analogue output dAA [s]
0…99.99
2-wire
Step response time analogue output [ms]
30
3-wire
Min. response time of switching output (dAP) [ms]
3
Step response time analogue output [ms]
7
Temperature monitoring
Dynamic response T05 / T09 [s]
< 35 / < 135; (DIN EN 60751 water ; > 0,9 m/s)
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A)
threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Displays / operating elements
Display
Display unit
LED, green
switching status
LED, yellow
function display
alphanumeric display, 4-digit
measured values
alphanumeric display, 4-digit
Display unit
mbar; kPa; inH2O; mmWS
Remarks
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
Diagrams and graphs
X
temperature
Y
total deviation
Contact us via Facebook: