ThinkTop V50 and V70ThinkTop V50 and V70 are valve control units, they are interchangable with prior ThinkTop versions.
Burst seat clean functionDuring CIP, it’s common to run a sequence of seat lifts, to save CIP liquid this can be optimised by using the “Burst seat clean function”, this function secure full seat lift and then instantly close again, (avalable on V70).
ThinkTop V50 is for valves:Unique SSV, iSSV, SSSV, LKLA-T, SMP-BC, DV-ST, Shutter, SBV, Unique Mixproof.
(Except special valves; Long stroke, LKLA, Air/Air and 2-step actuators)
ThinkTop V70 is for valves:Unique SSV, iSSV, SSSV, LKLA-T, SMP-BC, DV-ST, Shutter, SBV, Unique Mixproof, Long stroke, Air/Air and 2-step actuators.
(Except special valves; LKLA)
BenefitsAutomatic setupAutomatic valve recognitionFast Auto, Live and Flex Setup360-degree LED indicationBurst clean function (V70)Interchangeable with prior ThinkTop versions
ThinkTop V20ThinkTop V20 valve control unit is a reliable, cost-effective control unit. It provides standard functionality for intuitive sensing of the valve position and status, displayed on the unit’s 360° light-emitting diodes (LEDs).
BenefitsHighly accurate indication of hygienic valve positions within ± 1 mmHygienic design based on the ThinkTop V50 and V70Intuitive live setup for fast installationDigital, AS-I or IO-Link interfacesCompatible with Alfa Laval hygienic valves with standard mushroom connections, making it easy to upgrade older valve indication units360-degree LED indication
IndiTopThe indication unit IndiTop is designed as a basic and easy to use, electrical feedback unit for Alfa Laval sanitary valves.BenefitsWorks with both DC and AC supply voltage (8-30V DC/AC)Two PNP/NPN digital DC/AC feedback signalsKeeps the setup during power downsVisual indication through LEDs
Mô tả
ThinkTop V50 and V70 ThinkTop V50 and V70 are valve control units, they are interchangable with prior ThinkTop versions.
Burst seat clean function During CIP, it’s common to run a sequence of seat lifts, to save CIP liquid this can be optimised by using the “Burst seat clean function”, this function secure full seat lift and then instantly close again, (avalable on V70).
ThinkTop V50 is for valves: Unique SSV, iSSV, SSSV, LKLA-T, SMP-BC, DV-ST, Shutter, SBV, Unique Mixproof.
(Except special valves; Long stroke, LKLA, Air/Air and 2-step actuators)
ThinkTop V70 is for valves: Unique SSV, iSSV, SSSV, LKLA-T, SMP-BC, DV-ST, Shutter, SBV, Unique Mixproof, Long stroke, Air/Air and 2-step actuators.
(Except special valves; LKLA)
Benefits Automatic setup Automatic valve recognition Fast Auto, Live and Flex Setup 360-degree LED indication Burst clean function (V70) Interchangeable with prior ThinkTop versions
ThinkTop V20 ThinkTop V20 valve control unit is a reliable, cost-effective control unit. It provides standard functionality for intuitive sensing of the valve position and status, displayed on the unit’s 360° light-emitting diodes (LEDs).
Benefits Highly accurate indication of hygienic valve positions within ± 1 mm Hygienic design based on the ThinkTop V50 and V70 Intuitive live setup for fast installation Digital, AS-I or IO-Link interfaces Compatible with Alfa Laval hygienic valves with standard mushroom connections, making it easy to upgrade older valve indication units 360-degree LED indication
IndiTop The indication unit IndiTop is designed as a basic and easy to use, electrical feedback unit for Alfa Laval sanitary valves. Benefits Works with both DC and AC supply voltage (8-30V DC/AC) Two PNP/NPN digital DC/AC feedback signals Keeps the setup during power downs Visual indication through LEDs
Supply control board: 24 VDC
Supply control board: 24 VDC
Supply control board: 29.5-31.6 VDC
Supply control board: 29.5-31.6 VDC
Supply control board: 24 VDC
Supply control board: 29.5-31.6 VDC
Supply control board: 24 VDC
Supply control board: 29.5-31.6 VDC
Electrical connection: M12
Supply control board: 24 VDC ± 10 %
Electrical connection: M12
Supply control board: 29.5 – 31.6 VDC
Electrical connection: M12
Supply control board: 24 VDC ± 10 %
Electrical connection: M12
Supply control board: 24 VDC ± 10 %
_______________________________