Tetra Pak offer a wide range of temperature transmitters. This page shows a selection of the available variants.
Contact your Tetra Pak representative to get more information.
TM311, IO-LinkApplicationTM311 is used for temperature measuring in hygienic and aseptic applications in the food, beverage and pharmaceutical industries with IO-Link digital protocolGeneralThe compact thermometer measures the process temperature using a Pt100 sensor element (Class A, 4-wire). An optional integrated transmitter converts the Pt100 input signal. In the version with integrated electronics, the device automatically detects the connection variant (IO-Link or 4–20 mA).BenefitsIO-Link output signal is a new trending industrial point to point digital communication protocol and has various advantagesTM311 has a sensor+transmitter matched option which has increased accuracy up to 0.14 CSuitable for pipe and tank applicationsEHEDG approved process connection varietyThermowell and without thermowell options with fast response time
TPT12, with and without cableApplicationTPT12 is used for temperature measuring in pipelines, dimensions DN 25 – 100.BenefitsHigh accuracyBuilt-in transmitter = No need for transmitters in cabinet (saves space).Smaller sensor point lowers the risk of reading errors due to stem heat.Possible to use the existing wiring when you replace it with an existing sensor only adding a connector (and removing transmitter in cabinet).TPT31ApplicationTPT31 is used for temperature measuring in pipelines, dimensions DN 25 – 100.BenefitsHigher accuracy than TPT12Digital transmitter = No need for transmitters or analogue input cards in cabinet (saves space and cost).Smaller sensor point lowers the risk of reading errors due to stem heat.Possible to get diagnostics from transmitter.EAC approved TPT12 and TPT31Same type of transmitters as above, but EAC marked as they conform to technical regulations of the Euroasian Customs Union.
TM411ApplicationTM411 is used for temperature measuring in tanks and in projects.BenefitsHigh accuracy Built-in transmitter = No need for transmitters in cabinet (saves space).
Weld in connections
Description
Denomination
Part No
Add to cart
For TPT12
See “Accessories, temperature”
For TM311, TMR35 and TM411
See “Accessories pressure”
TM311 Compact Resistance Thermometer
Description
Denomination
Range_C°
Part No
Add to cart
TM311, Threaded G1″
Direct contact
4_20mA+IO-Link
M12, IP69K
316L_housing_and_probe_material
0.76um surface roughness
Standard accuracy 0.5 °C
1.5s T90 – response time
RTD, TM311 G1″ L=50.00mm
0-150
90532-7948
RTD, TM311 G1″ L=80.00mm
0-150
90532-7949
RTD, TM311 G1″ L=100.00mm
0-150
90532-7950
RTD, TM311 G1″ L=200.00mm
0-150
90532-7951
RTD, TM311 G1″ L=300.00mm
0-150
90532-7952
TM311, Clamp
Direct contact
4_20mA+IO-Link
M12, IP69K
316L housing and probe material
0.76um surface roughness
Standard accuracy 0.5 °C
1.5s T90 – response time
RTD, TM311 Cl.DN25-38 L=40.00mm
0-200
90532-5566
RTD, TM311 Cl.DN25-38 L=40.00mm
0-150
90532-5567
RTD, TM311 Cl.DN25-38 L=50.00mm
0-150
90532-5568
RTD, TM311 Cl.DN25-38 L=50.00mm
0-200
90532-5569
RTD, TM311 Cl.DN25-38 L=70.00mm
0-150
90532-5570
RTD, TM311 Cl.DN25-38 L=70.00mm
0-200
90532-5571
RTD, TM311 Cl.DN25-38 L=80.00mm
0-150
90532-5572
RTD, TM311 Cl.DN25-38 L=80.00mm
0-200
90532-5573
RTD, TM311 Cl.DN25-38 L=100.00mm
0-150
90532-7901
RTD, TM311 Cl.DN25-38 L=200.00mm
0-150
90532-7902
RTD, TM311 Cl.DN25-38 L=300.00mm
0-150
90532-7903
TM311, Clamp
Direct contact
4_20mA+IO-Link
M12, IP69K
316L housing and probe material
0.76um surface roughness
High accuracy 0.14 °C + 3 point calibration certificate
1.5s T90 – response time
RTD, TM311 Cl.DN25-38 L=40.00mm
0-150
90532-5543
RTD, TM311 Cl.DN25-38 L=50.00mm
0-150
90532-5544
RTD, TM311 Cl.DN25-38 L=70.00mm
0-150
90532-5545
RTD, TM311 Cl.DN25-38 L=80.00mm
0-150
90532-5546
TM311, Varivent
Direct contact
4_20mA+IO-Link
M12, IP69K
316L housing and probe material
0.76um surface roughness
Standard accuracy 0.5 °C
1.5s T90 – response time
RTD, TM311 Varivent Fl.50 L=20.00mm
0-150
90532-7931
RTD, TM311 Varivent Fl.50 L=20.00mm
0-200
90532-7932
RTD, TM311 Varivent Fl.68 L=30.00mm
0-200
90532-7936
RTD, TM311 Varivent Fl.68 L=30.00mm
0-150
90532-7937
RTD, TM311 Varivent Fl.68 L=50.00mm
0-150
90532-7941
RTD, TM311 Varivent Fl.68 L=50.00mm
0-200
90532-7942
RTD, TM311 Varivent Fl.68 L=70.00mm
0-150
90532-7946
RTD, TM311 Varivent Fl.68 L=70.00mm
0-200
90532-7947
TM311, Clamp (with thermowell)
With built-in thermowell CSA/US marked
4_20mA+IO-Link
M12, IP69K
316L housing and probe material
0.76um surface roughness
Standard accuracy 0.5 °C
3.0s T90 – response time
Mô tả
Tetra Pak offer a wide range of temperature transmitters.
This page shows a selection of the available variants.
Contact your Tetra Pak representative to get more information.
TM311, IO-Link Application TM311 is used for temperature measuring in hygienic and aseptic applications in the food, beverage and pharmaceutical industries with IO-Link digital protocol General The compact thermometer measures the process temperature using a Pt100 sensor element (Class A, 4-wire). An optional integrated transmitter converts the Pt100 input signal. In the version with integrated electronics, the device automatically detects the connection variant (IO-Link or 4–20 mA). Benefits IO-Link output signal is a new trending industrial point to point digital communication protocol and has various advantages TM311 has a sensor+transmitter matched option which has increased accuracy up to 0.14 C Suitable for pipe and tank applications EHEDG approved process connection variety Thermowell and without thermowell options with fast response time
TPT12, with and without cable Application TPT12 is used for temperature measuring in pipelines, dimensions DN 25 – 100. Benefits High accuracy Built-in transmitter = No need for transmitters in cabinet (saves space). Smaller sensor point lowers the risk of reading errors due to stem heat. Possible to use the existing wiring when you replace it with an existing sensor only adding a connector (and removing transmitter in cabinet). TPT31 Application TPT31 is used for temperature measuring in pipelines, dimensions DN 25 – 100. Benefits Higher accuracy than TPT12 Digital transmitter = No need for transmitters or analogue input cards in cabinet (saves space and cost). Smaller sensor point lowers the risk of reading errors due to stem heat. Possible to get diagnostics from transmitter. EAC approved TPT12 and TPT31 Same type of transmitters as above, but EAC marked as they conform to technical regulations of the Euroasian Customs Union.
TM411 Application TM411 is used for temperature measuring in tanks and in projects. Benefits High accuracy
Built-in transmitter = No need for transmitters in cabinet (saves space).
See “Accessories, temperature”
See “Accessories pressure”
Direct contact
4_20mA+IO-Link
M12, IP69K
316L_housing_and_probe_material
0.76um surface roughness
Standard accuracy 0.5 °C
1.5s T90 – response time
Direct contact
4_20mA+IO-Link
M12, IP69K
316L housing and probe material
0.76um surface roughness
Standard accuracy 0.5 °C
1.5s T90 – response time
Direct contact
4_20mA+IO-Link
M12, IP69K
316L housing and probe material
0.76um surface roughness
High accuracy 0.14 °C + 3 point calibration certificate
1.5s T90 – response time
Direct contact
4_20mA+IO-Link
M12, IP69K
316L housing and probe material
0.76um surface roughness
Standard accuracy 0.5 °C
1.5s T90 – response time
With built-in thermowell CSA/US marked
4_20mA+IO-Link
M12, IP69K
316L housing and probe material
0.76um surface roughness
Standard accuracy 0.5 °C
3.0s T90 – response time