Number of digital outputs: 2; Number of analogue outputs: 1
Process connection
G 3/4 DN20 flat seal
Application
Special feature
Gold-plated contacts
Media
conductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]
-20…90
Pressure rating [bar]
16
Electrical data
Operating voltage [V]
18…30 DC; (to SELV/PELV)
Current consumption [mA]
< 80
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
5
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputs
counter reset
Outputs
Total number of outputs
2
Output signal
switching signal; analogue signal; pulse signal; IO-Link; frequency signal; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
100
Number of analogue outputs
1
Analogue current output [mA]
4…20; (scalable)
Max. load [Ω]
500
Pulse output
flow rate meter
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
Measuring/setting range
Measuring range
0.1…75 l/min
0.006…4.5 m³/h
1.2…1190 gph
0.02…19.82 gpm
Display range
-90…90 l/min
-5.4…5.4 m³/h
-1426.8…1426.8 gph
-23.78…23.78 gpm
Resolution
0.1 l/min
0.006 m³/h
0.6 gph
0.01 gpm
Set point SP
0.5…75 l/min
0.03…4.5 m³/h
8.4…1189 gph
0.14…19.81 gpm
Reset point rP
0.1…74.6 l/min
0.006…4.48 m³/h
1.2…1183 gph
0.03…19.71 gpm
Analogue start point ASP
0…59.9 l/min
0…3.6 m³/h
0…950 gph
0…15.82 gpm
Analogue end point AEP
15.1…75 l/min
0.9…4.5 m³/h
240…1189 gph
3.99…19.81 gpm
Low flow cut-off LFC
0.1…3.8 l/min
0.006…0.23 m³/h
1.8…59.4 gph
0.03…0.99 gpm
Frequency end point, FEP
15.1…75 l/min
0.9…4.5 m³/h
240…1189 gph
3.99…19.81 gpm
Frequency at the end point FRP [Hz]
1…10000
Volumetric flow quantity monitoring
Pulse length [s]
0.003…2
Pulse value
0.01…99990000 I
Temperature monitoring
Measuring range [°C]
-20…90
Display range [°C]
-42…112
Resolution [°C]
0.1
Set point SP [°C]
-19.6…90
Reset point rP [°C]
-20…89.6
Analogue start point [°C]
-20…68
Analogue end point [°C]
2…90
In steps of [°C]
0.1
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range)
± (0,8 % MW + 0,2 % MEW)
Repeatability
± 0,2 % MEW
Temperature monitoring
Accuracy [K]
± 2,5 (Q > 5 % MEW)
Response times
Flow monitoring
Start-up delay [s]
0…50
Response time [s]
< 0.25; (dAP = 0, T09)
Damping process value dAP [s]
0…5
Temperature monitoring
Response time [s]
15; (Q > 10 % MEW, T09)
Software / programming
Parameter setting options
hysteresis / window; normally open / normally closed; switching logic; frequency output; current/pulse output; start-up delay; display can be deactivated; Display unit
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode
yes
Required master port type
A
Process data analogue
3
Process data binary
2
Min. process cycle time [ms]
6
Supported DeviceIDs
Type of operation
DeviceID
Default
955
Operating conditions
Ambient temperature [°C]
-20…60
Storage temperature [°C]
-25…80
Protection
IP 65; IP 67
Tests / approvals
EMC
DIN EN 60947-5-9
CPA approval
model number
006MI
accuracy class
–
maximum allowable error
± 1,0 % FS
Q (min)
0,006 m³/h
Q (t)
–
Q (max)
4,5 m³/h
Shock resistance
DIN IEC 68-2-27
20 g (11 ms)
Vibration resistance
DIN IEC 68-2-6:
5 g (10…2000 Hz)
MTTF [years]
114
UL approval
UL Approval no.
I014
File number UL
E174189
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request